So Kevin hit an issue where he ran the CEICW on a brand new SBS 2003 computer and hit this:

http://groups.google.com/group/microsoft.public.windows.server.sbs/browse_thread/thread/ed5a595e5c3fd88c/50b71975e02617db?lnk=st&q=Error+0x80070057+returned+from+call+to+Adding+routers+IP+address+to+the+intranet+zone().#50b71975e02617db

Error 0x80070057 returned from call to Adding routers IP address to
the intranet zone().

So how did he fix this?  Two things.

He imported the registry key from a working computer

HKEY_CURRENT_USER\Software\Microsoft\Windows\CurrentVersion\InternetSettings\ZoneMap

And then turned off Enhanced IE and bingo.. the CEICW wizard worked.

 

3 Responses to Error 0x80070057 returned from call to Adding routers IP address

  1. Simon says:

    I encountered the same problem a few weeks ago when setting up a new HP ProLiant server with the latest version of the HP SmartStart CD (perhaps it’s a bug?). I haven’t struck this problem with earlier versions of the HP SmartStart CD.

  2. Perry says:

    Thanks so much for shedding light on this! Like Simon, I’m working with an HP ProLiant assisted with SmartStart. If that is the culprit, I have another name….and it ain’t smart.

  3. milenz says:

    Had the same problem, but didn’t have to import the registry key. Simply uninstalling IE enhanced security configuration worked for me.